|

|
|
|
|
Basic setup of the SR868C8
Maximum cylinder temperature
By default, the controller sets the maximum cylinder temperature to 600C.This should only be changed if a temperature mixing valve is fitted. The SMX (Stop pump p1 if MaXimum tank temperature reached) setting can be accessed from the TEMP menu. To change SMX setting in the controller input the following: Press ESC1. Press SET the PWD screen appears, first digit is adjustable using +/- (or SET to move to next digit) 2. Press SET the PWD screen appears, second digit is adjustable using +/-3. Press SET the PWD screen appears, third digit is adjustable using +/- 4. Press SET the PWD screen appears, fourth digit four is adjustable using +/- 5. Press SET DT O appears 6. Press + DT F appears 7. Press + tHET appears 8. Press + TEMP appears9. Press SET EMOF appears10. Press + EMON appears11. Press + CMx appears12. Press + CMN appears13. Press + CFR appears14. Press + SMX appears 15. Press SET the existing value is shown (600C.) 16. Press +/- until ? 75 ? (adjust to your chosen value) is displayed 17. Press ESC to confirm setting.18. Press ESC TEMP appears19. Press ESC Home screen appears
|
 |

|
|
|
|